Skip to Content

Fanuc 7115 Alarm [2021]

: Incorrectly set spindle initialization parameters or winding switching settings in the ladder diagram can cause the system to look for feedback that never arrives. Troubleshooting and Solutions

: Verify if the contactors physically move when the spindle tries to switch gears. If they are stuck or burnt, they may need replacement. fanuc 7115 alarm

The spindle speed switching contactors are not pulling in correctly during power-on or mode switching. 24VDC Power Supply Failure: fanuc 7115 alarm

Manually check if the high/low range contactors are physically sticking or if their coils are burned out. Verify Proximity Switches: fanuc 7115 alarm

: In some cases, a hard restart can clear transient communication glitches.

As The Bunny Hops®